|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Step | Action | |
|---|---|---|
|
1 |
Check the Media Kit in the FAS270 packaging for the version level of Data ONTAP to be installed on the FAS270. Compare it to the version level of Data ONTAP that is installed on the FAS250. |
|
|
2 |
If Data ONTAP on the FAS250 is... |
Then... |
|
The same as or a later version than the FAS270 |
||
|
An earlier version than the FAS270 |
software install software_file
download
|
|
The FAS270 node is shipped without an image on its CompactFlashTM card. After installing the new FAS270 node, you must perform a netboot process on Data ONTAP so that you can download the correct files to the CompactFlash card for subsequent system boots.
The two main methods of performing the netboot process are as follows:
To copy the Data ONTAP boot image to a local HTTP server for the netboot process, complete the following steps.
| Step | Action | |
|---|---|---|
| 1 |
Copy the netapp-mips file from the /etc/boot directory on the FAS250 and copy it to a Web server that can access the FAS250. Note: You can also copy this file from http://now/netapp.com/NOW/main/software.shtml to your local Web server. |
|
| 2 |
Halt the system by entering the following command: halt Note: The system begins beeping two minutes after Data ONTAP stops. |
|
| 3 |
If DHCP is... |
Then... |
| Running |
Configure the connection automatically by entering the following command at the CFE prompt: ifconfig e0a -auto |
|
| Not running |
Manually configure the connection by entering the following command at the CFE prompt: ifconfig e0a -addr= filer_addr -mask= netmask -gw= gateway \ -dns= dns_addr -domain= dns_domain |
|
|
Test the netboot process by entering the appropriate command from the node console: Automatically use the netboot process through the HTTP server:netboot http:// webserver.com / file_path / netboot_file_name Manually use the netboot process through the TFTP server:netboot tftp:// webserver.com / file_path / netboot_file_name webserver.com is the name of the Web server where you copied the netboot file. file_path is the path to the netboot file. netboot_file_name is the name of the netboot file. See Help netboot for more information. |
||
To convert the FAS250 hardware, complete the following steps, using the illustration for reference.

| Step | Action | |
|---|---|---|
|
1 |
Halt the system, turn off the power to the FAS250, and remove all cabling from the system. Make sure that you are properly grounded. |
|
|
2 |
Remove the FAS250 node and replace it with the new FAS270 node. |
|
|
3 |
Connect the system to the network through port A on the on-board Ethernet adapter, and then recable the console and reconnect the system to the power source. |
|
|
4 |
Set the terminate switch on the node to On. |
|
|
5 |
Go to Completing the upgrade. |
|
To complete the upgrade to the FAS270, complete the following steps.
| Step | Action | |
|---|---|---|
|
1 |
Turn on the system and press any key to boot to the CFE prompt. Perform the netboot process on the system, as described in Preparing for the netboot process, Step 3 and Step 4. |
|
|
2 |
Press Ctrl-C during boot and select 5 from the displayed menu to enter Maintenance Mode. Answer the displayed questions. |
|
|
3 |
Check ownership by entering the following command: disk show Result: The disks are all unassigned. |
|
|
4 |
Assign disk ownership to the FAS270 by entering the following command: disk assign all |
|
|
5 |
Check ownership by entering the following command: disk show Result: The new FAS270 should own all the disks. |
|
|
6 |
Halt the system. |
|
|
7 |
Exit Maintenance Mode, and then perform a netboot process on the system through a normal boot, as described in Preparing for the netboot process, Step 3 and Step 4. |
|
|
8 |
Download the installed image to the CompactFlash card by entering the following command: download |
|
|
9 |
Verify that the Data ONTAP image transferred to the CompactFlash card by entering the following command: version -b |
|
|
10 |
Reboot the system to verify that the CompactFlash card is the default boot device for Data ONTAP by entering the following command: reboot |
|
|
11 |
Modify the RAID groups and volumes, as needed, as described in the Storage Management Guide. |
|
|
12 |
If you are... |
Then... |
|
Upgrading to a cluster |
Go to Upgrading to a FAS270c. |
|
|
Adding storage to the system |
Go to Adding storage. |
|
|
Upgrading to a single CPU FAS270 with no additional storage |
Go to Decommissioning the FAS250. |
|
Preparing the FAS270 for upgrade to a cluster is a two-step process:
This procedure assumes the following:
The following illustration
shows the arrangement of the individual nodes in a FAS270c.

Use the following worksheet to identify disk ownership in your system. You should note the location of root and data volumes and the location of unused or unassigned disks. Node A is not initially installed in the system. It is installed in Preparing Node A.
You must have four spares available:
If all disks are full on Node B or there are not enough spare disks on the system, you must add a disk shelf or disk shelves to the system, as described in Adding storage.
| Disk Assignments - Disk Shelf #1 | Node B | Node A | Disk Assignments - Disk Shelf #2 | Node B | Node A |
|---|---|---|---|---|---|
|
Disk 0--0b.16 |
_______ |
_______ |
Disk 0--0b.32 |
_______ |
_______ |
|
Disk 1--0b.17 |
_______ |
_______ |
Disk 1--0b.33 |
_______ |
_______ |
|
Disk 2--0b.18 |
_______ |
_______ |
Disk 2--0b.34 |
_______ |
_______ |
|
Disk 3--0b.19 |
_______ |
_______ |
Disk 3--0b.35 |
_______ |
_______ |
|
Disk 4--0b.20 |
_______ |
_______ |
Disk 4--0b.36 |
_______ |
_______ |
|
Disk 5--0b.21 |
_______ |
_______ |
Disk 5--0b.37 |
_______ |
_______ |
|
Disk 6--0b.22 |
_______ |
_______ |
Disk 6--0b.38 |
_______ |
_______ |
|
Disk 7--0b.23 |
_______ |
_______ |
Disk 7--0b.39 |
_______ |
_______ |
|
Disk 8--0b.24 |
_______ |
_______ |
Disk 8--0b.40 |
_______ |
_______ |
|
Disk 9--0b.25 |
_______ |
_______ |
Disk 9--0b.41 |
_______ |
_______ |
|
Disk 10--0b.26 |
_______ |
_______ |
Disk 10--0b.42 |
_______ |
_______ |
|
Disk 11--0b.27 |
_______ |
_______ |
Disk 11--0b.43 |
_______ |
_______ |
|
Disk 12--0b.28 |
_______ |
_______ |
Disk 12--0b.44 |
_______ |
_______ |
|
Disk 13--0b.29 |
_______ |
_______ |
Disk 13--0b.45 |
_______ |
_______ |
Note: You must assign drive bay 0 on disk shelves 2 and 3 to one node and drive bay 1 to the other node. This allows both nodes to have SES access to each shelf.
To configure the FAS270 into a clustered system, complete the following steps, using the figure for reference.
| Step | Action | |
|---|---|---|
|
1 |
Complete the disk ownership worksheet, as described in Disk reservation and ownership worksheet. To determine disk ownership, enter the following command: disk show -v To determine the list of spares, enter the following command: vol status -s |
|
| 2 |
If there are... |
Then... |
|
Four or more spare disks |
disk assign 0b.nn -s unowned -f
|
|
|
Three or fewer spare disks |
Complete Steps 3 through 5, and then add disk shelves, as described in Step 6. |
|
| 3 |
Shut down the system and unplug it from the power source. Make sure that you are properly grounded with a grounding strap. |
|
| 4 |
Remove the CPU blank and install Node A. Make sure that you install it inverted from the first module. The module is keyed to prevent improper installation. |
|
| 5 |
Connect Node A to its own console and to the network. |
|
| 6 |
Install any additional disk shelves, as described in Adding storage. |
|
| 7 |
Turn on both nodes. On the console of the new node, press any key to stop the system at the CFE prompt. Perform a netboot process on the system, as described in Preparing for the netboot process, Step 3 and Step 4. |
|
| 8 |
Press Ctrl-C during boot and select 4 from the displayed menu. Result: The node attempts to assign any unassigned disks for its use. You are prompted to zero these disks. Answer Y to the two displayed questions. Caution: Make sure that you are on the correct console for the new node. If you are not on the correct console, CFE Option 4 removes data. |
|
| 9 |
Complete the initial setup by answering the questions with information for the new node. |
|
| 10 |
License products you need to complete the download by entering the following command for each product: license add xxxx9> xxxx is the license code for the product. |
|
| 11 |
Install Data ONTAP on the new node. Make sure that you download the image to the CompactFlash card and reboot the system. |
|
| 12 |
Verify the contents of the CompactFlash card by entering the following command: version -b |
|
| 13 |
Reboot the node to verify that the CompactFlash card is the default boot device for Data ONTAP by entering the following command: reboot |
|
|
14 |
Go to Configuring for clustering. |
|
To configure the system for clustering, complete the following steps.
| Step | On Node B... | On Node A... |
|---|---|---|
| 1 |
Enable licenses on both nodes by entering the following command on each node's console: license add xxxxNote: Make sure that you license clustering on both nodes. |
|
| 2 |
Reboot the node. |
Reboot the node after adding the cluster license. |
| 3 |
Enable clustering by entering the following command: cf enable |
No action |
|
4 |
Check node status by entering the following command: cf status |
|
| 5 |
Test takeover by completing the following steps:
cf takeover Result: Takeover succeeds. If not, run the Cluster Configuration Checker, fix any errors, reboot the node, and repeat the test.
cf status
cf giveback
cf status |
Test takeover
by completing the following steps:
|
| 6 | No action |
Assign any unassigned disks or spares, as needed. |
| 7 | No action |
Configure RAID groups and volumes, as described in the Storage Management Guide. |
| 8 |
Complete the setup, as described in the Software Setup Guide. |
|
To add disk shelves to your system, up to the maximum supported by the system, complete the following steps.
| Step | Action | |
|---|---|---|
|
1 |
Install the disk shelves in the equipment rack, as described in the DiskShelf14 and DiskShelf14mk2 FC Hardware Guide. |
|
| 2 |
If you are installing a... |
Then... |
|
Single node FAS270 |
|
|
|
FAS270 cluster |
|
|
The following procedure assumes that you are taking the FAS250 completely out of service and returning it to Network Appliance. To complete the decommissioning process, complete the following steps.
| Step | Action |
|---|---|
| 1 |
Decommission the system through the NOW Web site at http://now.netapp.com/. Search for Decommission this System and follow the instructions. |
| 2 |
Return the FAS250 node to NetApp, as described in the SRA instructions shipped with the conversion kit. Contact Customer Support if you need the SRA instructions. |
Part Number: 215-00744
Last updated: November 20, 2003