images/nav1.gif (4223 bytes)

 

 

Upgrading a FAS250 

to a FAS270 or FAS270c




About these instructions

These instructions are for NetApp® trained personnel to upgrade from a FAS250 to a FAS270 or FAS270c.

These instructions describe the following procedures:

Required software, firmware, and manuals

The following list specifies the software, firmware, and manuals you need to complete the upgrade:

  • Data ONTAPTM 6.5 software or later
Caution: Data ONTAP is designed for specific filer families. You must install the same version level of Data ONTAP for your filer family.
  • Filer firmware CFE 1.1 (common firmware environment) or later for the FAS250 and FAS270
  • FAS250-to-FAS270 upgrade kit 
  • FAS270 Series Hardware and Service Guide 
  • FAS250 Series Hardware and Service Guide 
  • Software Setup Guide

Upgrading to a single-node FAS270

About upgrading the FAS250

Upgrading the FAS250 is a four-step process:

Assumptions about the upgrade

These procedures assume the following:

  • You have access to an HTTP server for the netboot process.
  • You backed up your FAS250 system before beginning the conversion procedure.

Preparing the FAS250

To prepare the FAS250 for upgrade to a FAS270, complete the following steps.

Step Action

1

Check the Media Kit in the FAS270 packaging for the version level of Data ONTAP to be installed on the FAS270. Compare it to the version level of Data ONTAP that is installed on the FAS250.

2

If Data ONTAP on the FAS250 is...
Then...

The same as or a later version than the FAS270

Go to Preparing for the netboot process.

An earlier version than the FAS270

  1. Download Data ONTAP to a client or Web server from http://now/netapp.com/NOW/main/software.shtml.
  2. Extract and install the files by entering one of the following commands from the console:
software install software_file

or

software install url

software_file is the name of the file on the CPU module.

url is the location of the software in a Web server.

Note: In a Windows® environment, you must unzip the files and run setup.exe.

  1. Download the image by entering the following command:
download
  1. Reboot the system.

Preparing for the netboot process

The FAS270 node is shipped without an image on its CompactFlashTM card. After installing the new FAS270 node, you must perform a netboot process on Data ONTAP so that you can download the correct files to the CompactFlash card for subsequent system boots.

The two main methods of performing the netboot process are as follows:

  • Through an HTTP server with DHCP running
  • Through a TFPT server, manually setting ifconfig

To copy the Data ONTAP boot image to a local HTTP server for the netboot process, complete the following steps.

Step Action
1

Copy the netapp-mips file from the /etc/boot directory on the FAS250 and copy it to a Web server that can access the FAS250.

Note: You can also copy this file from http://now/netapp.com/NOW/main/software.shtml to your local Web server.

2

Halt the system by entering the following command:

halt

Note: The system begins beeping two minutes after Data ONTAP stops.

3
If DHCP is...
Then...
Running

Configure the connection automatically by entering the following command at the CFE prompt:

ifconfig e0a -auto
Not running

Manually configure the connection by entering the following command at the CFE prompt:

ifconfig e0a -addr= filer_addr -mask= netmask -gw= gateway \
-dns= dns_addr -domain= dns_domain

4

Test the netboot process by entering the appropriate command from the node console:

Automatically use the netboot process through the HTTP server:
netboot http:// webserver.com / file_path / netboot_file_name
Manually use the netboot process through the TFTP server:
netboot tftp:// webserver.com / file_path / netboot_file_name

webserver.com is the name of the Web server where you copied the netboot file.

file_path is the path to the netboot file.

netboot_file_name is the name of the netboot file.

See Help netboot for more information.

Converting the hardware

To convert the FAS250 hardware, complete the following steps, using the illustration for reference.

Step Action

1

Halt the system, turn off the power to the FAS250, and remove all cabling from the system. Make sure that you are properly grounded.

2

Remove the FAS250 node and replace it with the new FAS270 node.

3

Connect the system to the network through port A on the on-board Ethernet adapter, and then recable the console and reconnect the system to the power source.

4

Set the terminate switch on the node to On.

5

Go to Completing the upgrade.

Completing the upgrade

To complete the upgrade to the FAS270, complete the following steps.

Step Action

1

Turn on the system and press any key to boot to the CFE prompt. Perform the netboot process on the system, as described in Preparing for the netboot process, Step 3 and Step 4.

2

Press Ctrl-C during boot and select 5 from the displayed menu to enter Maintenance Mode. Answer the displayed questions.

3

Check ownership by entering the following command:

disk show

Result: The disks are all unassigned.

4

Assign disk ownership to the FAS270 by entering the following command:

disk assign all

5

Check ownership by entering the following command:

disk show

Result: The new FAS270 should own all the disks.

6

Halt the system.

 7

Exit Maintenance Mode, and then perform a netboot process on the system through a normal boot, as described in Preparing for the netboot process, Step 3 and Step 4.

8

Download the installed image to the CompactFlash card by entering the following command:

download

9

Verify that the Data ONTAP image transferred to the CompactFlash card by entering the following command:

version -b

10

Reboot the system to verify that the CompactFlash card is the default boot device for Data ONTAP by entering the following command:

reboot

11

Modify the RAID groups and volumes, as needed, as described in the Storage Management Guide.

12

If you are...
Then...

Upgrading to a cluster

Go to Upgrading to a FAS270c.

Adding storage to the system

Go to Adding storage.

Upgrading to a single CPU FAS270 with no additional storage

Go to Decommissioning the FAS250.

Upgrading to a FAS270c

About upgrading to a FAS270c

Preparing the FAS270 for upgrade to a cluster is a two-step process:

Assumptions for upgrading to a FAS270c

This procedure assumes the following:

  • You completed the upgrade from a FAS250 to a single CPU FAS270, as described in Upgrading to a single-node FAS270.
  • You have four spare disks; one for the first node, Node B, two for root volumes on Node A (the second node), and one spare for Node A.
  • Node B owns the current file system.
  • A second console is attached to Node A.
  • You scheduled system down time to upgrade an active system.

What the system looks like

The following illustration shows the arrangement of the individual nodes in a FAS270c.

Disk reservation and ownership worksheet

Use the following worksheet to identify disk ownership in your system. You should note the location of root and data volumes and the location of unused or unassigned disks. Node A is not initially installed in the system. It is installed in Preparing Node A.

You must have four spares available:

  • One spare for Node B
  • Two spares for root volumes on Node A
  • One spare for Node A

If all disks are full on Node B or there are not enough spare disks on the system, you must add a disk shelf or disk shelves to the system, as described in Adding storage.

Disk Assignments - Disk Shelf #1 Node B Node A Disk Assignments - Disk Shelf #2 Node B

Node A

Disk 0--0b.16

_______

_______

Disk 0--0b.32

_______

_______

Disk 1--0b.17

_______

_______

Disk 1--0b.33

_______

_______

Disk 2--0b.18

_______

_______

Disk 2--0b.34

_______

_______

Disk 3--0b.19

_______

_______

Disk 3--0b.35

_______

_______

Disk 4--0b.20

_______

_______

Disk 4--0b.36

_______

_______

Disk 5--0b.21

_______

_______

Disk 5--0b.37

_______

_______

Disk 6--0b.22

_______

_______

Disk 6--0b.38

_______

_______

Disk 7--0b.23

_______

_______

Disk 7--0b.39

_______

_______

Disk 8--0b.24

_______

_______

Disk 8--0b.40

_______

_______

Disk 9--0b.25

_______

_______

Disk 9--0b.41

_______

_______

Disk 10--0b.26

_______

_______

Disk 10--0b.42

_______

_______

Disk 11--0b.27

_______

_______

Disk 11--0b.43

_______

_______

Disk 12--0b.28

_______

_______

Disk 12--0b.44

_______

_______

Disk 13--0b.29

_______

_______

Disk 13--0b.45

_______

_______

Note: You must assign drive bay 0 on disk shelves 2 and 3 to one node and drive bay 1 to the other node. This allows both nodes to have SES access to each shelf.

Preparing Node A

To configure the FAS270 into a clustered system, complete the following steps, using the figure for reference.

 

Step Action

1

Complete the disk ownership worksheet, as described in Disk reservation and ownership worksheet.

To determine disk ownership, enter the following command:

disk show -v

To determine the list of spares, enter the following command:

vol status -s
2
If there are...
Then...

Four or more spare disks

  1. Unassign ownership to at least three of the available spares by entering the following command:
disk assign 0b.nn -s unowned -f

0b.nn is the disk ID to unassign.

  1. Go to Step 3.

Three or fewer spare disks

Complete Steps 3 through 5, and then add disk shelves, as described in Step 6.

3

Shut down the system and unplug it from the power source. Make sure that you are properly grounded with a grounding strap.

4

Remove the CPU blank and install Node A. Make sure that you install it inverted from the first module. The module is keyed to prevent improper installation.

5

Connect Node A to its own console and to the network.

6

Install any additional disk shelves, as described in Adding storage.

7

Turn on both nodes.

On the console of the new node, press any key to stop the system at the CFE prompt. Perform a netboot process on the system, as described in Preparing for the netboot process, Step 3 and Step 4.

8

Press Ctrl-C during boot and select 4 from the displayed menu.

Result: The node attempts to assign any unassigned disks for its use. You are prompted to zero these disks. Answer Y to the two displayed questions.

Caution: Make sure that you are on the correct console for the new node. If you are not on the correct console, CFE Option 4 removes data.
9

Complete the initial setup by answering the questions with information for the new node.

10

License products you need to complete the download by entering the following command for each product:

license add xxxx

xxxx is the license code for the product.

11

Install Data ONTAP on the new node. Make sure that you download the image to the CompactFlash card and reboot the system.

12

Verify the contents of the CompactFlash card by entering the following command:

version -b
13

Reboot the node to verify that the CompactFlash card is the default boot device for Data ONTAP by entering the following command:

reboot

14

Go to Configuring for clustering.

Configuring for clustering

To configure the system for clustering, complete the following steps.

Step On Node B... On Node A...
1

Enable licenses on both nodes by entering the following command on each node's console:

license add xxxx
Note: Make sure that you license clustering on both nodes.
2

Reboot the node.

Reboot the node after adding the cluster license.

3

Enable clustering by entering the following command:

cf enable

No action

 4

Check node status by entering the following command:

cf status
5

Test takeover by completing the following steps:

  1. Initiate takeover by entering the following command:
cf takeover 

Result: Takeover succeeds. If not, run the Cluster Configuration Checker, fix any errors, reboot the node, and repeat the test.

  1. Check the status of the takeover by entering the following command:
cf status
  1. Give back the node by entering the following command:
cf giveback
  1. Check the status of the cluster to ensure that giveback was successful by entering the following command:
cf status
Test takeover by completing the following steps:
  1. Initiate takeover on the node,
  2. Check the status of the takeover.
  3. Give back the node.
  4. Check the status of the cluster to ensure that giveback was successful.
6 No action

Assign any unassigned disks or spares, as needed.

7 No action

Configure RAID groups and volumes, as described in the Storage Management Guide.

8

Complete the setup, as described in the Software Setup Guide.

Adding storage

Adding storage

To add disk shelves to your system, up to the maximum supported by the system, complete the following steps.

Step Action

1

Install the disk shelves in the equipment rack, as described in the DiskShelf14 and DiskShelf14mk2 FC Hardware Guide.

2 
If you are installing a...
Then...

Single node FAS270

  1. Connect the blue Fibre Channel port on the node to the disk shelf LRC B Input port.
  2. Cable any remaining disk shelves in the loop.
  3. If you have two additional disk shelves, complete this step. If you are only adding a single disk shelf, go to the next step in this process.

Connect the LRC Channel A Input port on the top disk shelf to the LRC Channel A Output port of the disk shelf below it in the loop.

  1. Plug the loopback plug into the Channel A LRC Input port in the disk shelf closest to the node.
  2. Set the Terminate switch on the node to Off.
  3. Set the Terminate switch on the last disk shelf module B to On.
  4. Set the loop speed on the disk shelves to 1 Gb.
  5. Connect the disk shelves to the power supply, and then turn them on.

FAS270 cluster

  1. Connect the blue Fibre Channel port on Node B to the disk shelf LRC B Input port.
  2. Connect the blue Fibre Channel port on Node A to the disk shelf LRC A Input port.
  3. Cable any remaining disk shelves in loop A and B.
  4. Set the Terminate switches on Node B and Node A to Off.
  5. Set the Terminate switches on the last disk shelf to On.
  6. Set the loop speed on the disk shelves to 1 Gb.
  7. Connect the disk shelves to the power supplies, and then turn them on.
  8. Go to Step 7 in Preparing Node A to complete setup.

Decommissioning the FAS250

Decommissioning your FAS250

The following procedure assumes that you are taking the FAS250 completely out of service and returning it to Network Appliance. To complete the decommissioning process, complete the following steps.

Step Action
1

Decommission the system through the NOW Web site at http://now.netapp.com/. Search for Decommission this System and follow the instructions.

2

Return the FAS250 node to NetApp, as described in the SRA instructions shipped with the conversion kit. Contact Customer Support if you need the SRA instructions.

 

 

Part Number: 215-00744